The Log class is an Itential Automation Platform (IAP) class which is used to output errors, warnings, and other information to the console or the IAP log files.
Accessing the Log Object
An instantiation of the Log class is made by IAP on startup. It is exposed as the global log
object. IAP applications and adapters may reference the log
object.
Example cog.js
/* global adapters */
/* global brokers */
/* global cogs */
/* global log */
...
function test(callback){
log.info("I am a log entry");
...
}
function debug(callback){
log.debug("reconciling:"+device);
...
}
Log Levels
Log levels are used to control the amount of information recorded. Each level has a severity associated with it. The Log class offers several levels of logging.
Method | Description |
---|---|
console | Deprecated. |
spam | Collect or output excessive or repetitive messages, large text files, large quantities of data such as search results; information which though relevant would clutter up the log file and render it unusable. |
trace | Minor events within functions. Like "breadcrumbs" within a function. |
debug | Major events such as successful data retrieval from an external system or the completion of a function. |
info | Successful status change; should be limited to one message per successful action. |
warn | Issues or unexpected behavior which does not impact functionality. |
error | Errors or failures in the code which impacts functionality. |
Note:
console.log
should not be used as it is not supported by IAP. The best practice is to use the log class.
Log levels are defined in the loggerProps
object of the properties.json
file in the IAP root directory.
- The log_level property determines the level for the log file.
- The console_level property determines the level for the console.
- In the properties.json example below, the log_level is set to info, which means any logging that has an equal or higher severity value than info will be written to
/var/log/pronghorn/pronghorn.log
(info, warn, error, debug,console,trace).- If the log_level were debug, IAP would monitor all log.debug messages through cogs and adapters and log that information.**
properties.json
...
"loggerProps": {
"description": "Logging",
"log_max_files": 100,
"log_max_file_size": 1048576,
"log_level": "info",
"log_directory": "/var/log/itential/",
"log_filename": "itential.log",
"log_timezone_offset": 0,
"console_level": "info"
},
...
Changing Log Levels in IAP
An administrator can modify the log_level
using the IAP Pronghorn Properties interface by navigating to: Settings > Properties > Logging.
As an example, to change the log_level
to debug
:
- Replace the value of the
log_level
property by changinginfo
todebug
. - Click SAVE (upper-right corner).